U0210
Generic (SAE) Basic entry
Lost Communication With 'Seat Control Module C'
Severity
Low
Typical repair cost
50 – 700 EUR
System
Network
What it means
U0210 is stored when a module on the vehicle network stops receiving messages from the 'Seat Control Module C'. The missing module may be unpowered, faulty or disconnected from the bus.
Advertisement728 × 90
Symptoms
- Several warning lights on at the same time
- Functions controlled by the affected module do not work
- Scan tool cannot communicate with one module
- Gauges dropping to zero or dashboard flickering
Common causes
- Blown fuse or no power supply to the 'Seat Control Module C'
- Poor ground for the module
- Damaged CAN/data bus wiring or connector
- Failed module
- Low battery voltage during cranking or after a jump start
How to diagnose
- Check which modules respond to a full system scan and which do not
- Verify fuses, power and ground at the 'Seat Control Module C' connector
- Measure CAN bus resistance between the two bus wires (about 60 ohms with the battery disconnected) and inspect the wiring
- Check battery voltage and charging system; low voltage causes many communication codes
- Replace or reprogram the module only after power, ground and bus wiring are confirmed
Frequently asked questions
Can I keep driving with U0210?
Yes. The fault does not affect safety or driveability, but it will keep the warning light on and may fail an inspection.
Will clearing U0210 fix it?
No. Clearing only erases the stored code; it returns as soon as the monitor runs again unless the cause is repaired.
Related codes
Nearby codes in this group
- U0209Lost Communication With 'Seat Control Module B'
- U0211Lost Communication With 'Seat Control Module D'
- U0208Lost Communication With 'Seat Control Module A'
- U0212Lost Communication With Steering Column Control Module
- U0207Lost Communication With Moveable Roof Control Module
- U0213Lost Communication With Mirror Control Module
- U0206Lost Communication With Folding Top Control Module
- U0214Lost Communication With Remote Function Actuation